E I DU PONT DE NEMOURS & CO INC -- CRONAR TINTS, BALANCERS AND BINDERS, 805J -- 8010-00N036000
===================== Product Identification =====================
Product ID:CRONAR TINTS, BALANCERS AND BINDERS, 805J
MSDS Date:01/01/1992
FSC:8010
NIIN:00N036000
=== Responsible Party ===
Company Name:E I DU PONT DE NEMOURS & CO INC
Address:1007 MARKET ST
Box:1635
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-7515
Emergency Phone Num:800-441-3637;800-424-9300(CHEMTREC)
CAGE:B0589
=== Contractor Identification ===
Company Name:E I DU PONT DE NEMOURS & CO
Address:RAKETSTRAAT, 100, RUE DE LA FUSEE
City:BRUSSEL
Country:BE
Phone:32-(0)15-401.505
CAGE:B0589
Company Name:E.I. DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515;800-441-9442
CAGE:18873
============= Composition/Information on Ingredients =============
Ingred Name:FATTY ACIDS,LINSEED-OIL,REACT PRODS
W/2AMINO2(HYDROMETH)1,3PROPAN&FORMALDE,POLYM W/BU; (ACRYLIC
POLYMER)
CAS:96591-17-2
Fraction by Wt: 37%
Ingred Name:ACETIC ACID, BUTYL ESTER; (BUTYL ACETATE). VP: 8 @ 20C.
CAS:123-86-4
RTECS #:AF7350000
Fraction by Wt: 37%
OSHA PEL:150 PPM;200 PPM STEL
ACGIH TLV:150 PPM;200 PPM STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:CARBON BLACK
CAS:1333-86-4
RTECS #:FF5800000
Fraction by Wt: 37%
OSHA PEL:3.5 MG/M3
ACGIH TLV:3.5 MG/M3
Ingred Name:ACETIC ACID, PENTYL ESTER; (PRIMARY AMYL ACETATE) (SARA
III). VP: 4 @ 20C.
CAS:628-63-7
RTECS #:AJ1925000
Fraction by Wt: 37%
OSHA PEL:100 PPM
ACGIH TLV:100 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Ingred Name:XYLENE (SARA III). VP: 25 @ 20C.
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 37%
OSHA PEL:100 PPM;150 PPM
ACGIH TLV:100 PPM/150 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:SUPP DATA:THE RESP MFR'S DIRECTIONS FOR RESP USE. DO NOT
PERMIT ANYONE WITHOUT PROTECTION IN THE PAINTING AREA.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INGEST:GI DISTRESS. INHAL: MAY CAUSE
NOSE & THROAT IRRIT. RPTD & PRLNGD OVEREXP TO SOLVS MAY LEAD TO
PERM BRAIN & NERV SYS DAM. EYE WATERING, HDCH, NAUS, DIZZ & LOSS OF
COORDINATION ARE SIGNS THAT SOL V LEVELS ARE TOO HIGH. SKIN/EYE:
MAY CAUSE IRRIT/BURNING OF EYES. RPTD/PRLNGD LIQ CONT MAY CAUSE
SKIN (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: IRRIT W/DISCOMFORT & DERM. BUTYL
ACETATE: MAY CAUSE ABNORM LIVER FUNCTION. TESTS FOR EMBRYOTOXIC
ACTIVITY IN ANIMALS HAS BEEN INCONCLUSIVE. HAS BEEN TOX TO FETUS IN
LAB ANIMALS AT DOSES THAT ARE TOX TO MOTHER. PRIMARY AMYL ACETATE:
RECURRENT OVEREXP MAY RSLT IN LIVER & KIDNEY INJURY. (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INGEST: CALL MD IMMEDIATELY AND HAVE THE NAMES OF INGREDIENTS
AVAILABLE. INHAL: IF AFFECTED BY INHAL OF VAP/SPRAY MIST, REMOVE TO
FRESH AIR. IF BREATHING DIFFICULTY PERSISTS, OR OCCURS LATER,
CONSULT MD. SKIN: WASH WITH SOAP AND WATER. IF IRRITATION OCCURS,
CONTACT MD. EYE: IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT
LEAST 15 MINUTES, CALL MD.
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:100F,38C
Lower Limits:0.2%
Upper Limits:13.1%
Extinguishing Media:WATER SPRAY, FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . WATER FROM FOG NOZZLES MAY BE USED TO COOL
CLOSED CONTAINERS TO PREVENT PRESSURE BUILD-UP.
Unusual Fire/Explosion Hazard:WHEN HEATED > THE FL PT, EMITS FLAMMABLE
VAPORS WHICH, WHEN MIXED WITH AIR, CAN BURN OR BE EXPLOSIVE. FINE
MISTS OR SPRAYS MAY BE FLAMMABLE AT TEMPS < FL PT.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA. REMOVE SOURCES OF IGNITION.
PREVENT SKIN CONTACT AND BREATHING OF VAPOR. WEAR A PROPERLY FITTED
VAPOR/PARTICULATE RESPIRATOR (NIOSH/MSHA APPROVED TC-23C). CONFINE
AND REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:OBSERVE LABEL PRECAUTIONS. KEEP AWAY
FROM HEAT, SPARKS AND FLAME. CLOSE CONTAINER AFTER EACH USE. GROUND
CONTAINERS WHEN POURING. DO NOT STORE > 120F.
Other Precautions:DO NOT SAND, FLAME CUT, BRAZE OR WELD DRY COATING
WITHOUT A NIOSH/MSHA APPROVED RESPIRATOR OR APPROPRIATE
VENTILATION.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:DO NOT BREATHE VAP/MISTS. WEAR PROPERLY FITTED
VAP/PARTICULATE RESP APPRVD BY NIOSH/MSHA (TC-23C) FOR USE W/PAINTS
DURING APPLICATION & UNTIL ALL VAPS & SPRAY MISTS ARE EXHSTD. IN
CONFINED SPACES/IN S ITUATIONS WHERE CONTINUOUS (SUPP DATA)
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME AND PATTERN TO
KEEP CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:COVERALLS ARE RECOMMENDED.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING OR SMOKING.
Supplemental Safety and Health
HLTH HAZ:HIGH XYLENE CONCS HAVE CAUSED EMBRYOTOXIC EFTS IN LAB ANIMALS.
RECURRENT OVEREXP MAY RSLT IN LIVER & KIDNEY INJURY. CAN BE
ABSORBED THRU SKIN IN HARMFUL AMTS.RESP PROT:SPRAY OPS ARE
TYPICAL/P ROPER RESP FIT IS NOT POSS, WEAR NIOSH/MSHA APPRVD
POS-PRESS, SUPPLIED-AIR RESP (TC-19C). IN ALL CASES, FOLLOW (ING 6)
================== Physical/Chemical Properties ==================
HCC:F4
Boiling Pt:B.P. Text:>129F,>54C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.9-1.6
Evaporation Rate & Reference:LESS THAN ETHER
Solubility in Water:MISCIBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:46-92
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE,
SMOKE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL I/A/W FEDERAL, STATE
AND LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their